SelfCooking Center® 101 E (10x1/1 GN) |
Capacity: |
10 x 1/1 GN |
Lengthwise loading for: |
1/1, 1/2, 2/3, 1/3, 2/8 GN |
Number of meals per day: |
80-150 |
Width: |
847 mm |
Depth: |
771 mm |
Height: |
1.017 mm |
Minimum distances (left, right, back): |
50 mm |
Recommended distance for service work (left): |
500 mm |
Minimum distance on left for heat sources: |
350 mm |
Water supply (pressure hose): |
3/4'' / Ø 1/2'' |
Water pressure (Flow pressure): |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
Minimum flow rate for filter and soft water system: |
6,3 l/h |
Water drain: |
DN 50 mm |
Connected load: |
19 kW |
Fuse protection: |
3 x 32 A |
Mains connection: |
3 NAC 400V |
"Moist heat" connection: |
18 kW |
"Dry heat" connection: |
18 kW |
Weight (net): |
135,5 kg |
Cable cross-section (Supplied with 2.5 m cable / without connector): |
5 x 4 mm2 |
Marks of conformity: |
CE, IPX5, VDE, UL, CUL, NSF, KEMA, PCT, GS, DVGW, SVGW, WRAS, KIWA |
Latent heat load: |
3.529 kJ/h |
Sensitive heat load: |
4.615 kJ/h |
Required air volume (unit free-standing in room): |
651 m3/h |
Required air volume (unit with one side against the wall): |
410 m3/h |
Required air volume (unit with two sides against the wall): |
260 m3/h |
® 101 G (10x1/1 GN) |
Capacity: |
10 x 1/1 GN |
Lengthwise loading for: |
1/1, 1/2, 2/3, 1/3, 2/8 GN |
Number of meals per day: |
80-150 |
Width: |
847 mm |
Depth: |
771 mm |
Height: |
1.017 mm |
Height incl. gas draft diverter: |
1.256 mm |
Minimum distances (left, right, back): |
50 mm |
Recommended distance for service work (left): |
500 mm |
Minimum distance on left for heat sources: |
350 mm |
Water supply (pressure hose): |
3/4'' / Ø 1/2'' |
Water pressure (Flow pressure): |
150-600 kPa / 0,15-0,6 Mpa / 1,5-6 bar |
Minimum flow rate for filter and soft water system: |
6,3 l/h |
Water drain: |
DN 50 mm |
Electricity connection: |
0,39 kW |
Weight (net): |
154.5 kg |
Fuse protection: |
1 x 16 A |
Mains connection: |
1 NAC 230 V |
Cable cross-section (Supplied with 2.5 m cable / without connector): |
3 x 2,5 mm2 |
Gas supply/connection: |
3/4" |
Connected flow pressure, natural gas H G20: |
18 - 25 mbar |
Connected flow pressure, natural gas L G25: |
20 - 30 mbar |
Connected flow pressure, liquefied gas G30: |
25 - 57,5 mbar |
Connected flow pressure, liquefied gas G31: |
25 - 57,5 mbar |
Exhaust gas duct: |
A3 (nur Typ 61), B13, B23 |
Rated thermal load Liquid gas LPG total: |
23 kW |
Rated thermal load Liquid gas LPG "Moist heat": |
21 kW |
Rated thermal load Liquid gas LPG "Dry heat": |
23 kW |
Rated thermal load natural gas total: |
21,5 kW |
Rated thermal load natural gas "Moist heat": |
20 kW |
Rated thermal load natural gas "Dry heat": |
21,5 kW |
Marks of conformity: |
CE, GS, KEMA, DVGW, SVGW, KIWA, IPX5, NSF, GASTEC QA, AGA/CSA, JIA, PCT |
Latent heat load: |
3.529 kJ/h |
Sensitive heat load: |
4.286 kJ/h |
Required air volume (unit free-standing in room): |
651 m3/h |
Required air volume (unit with one side against the wall): |
410 m3/h |
Required air volume (unit with two sides against the wall): |
260 m3/h |
For further details please contact; [email protected]
|